Date of Award
2002
Level of Access Assigned by Author
Open-Access Thesis
Degree Name
Master of Science (MS)
Advisor
C. T. Hess
Second Committee Member
Richard A. Morrow
Third Committee Member
Charles W. Smith
Abstract
The transfer coefficient of radon from water to air was investigated in schools. Kitchens, bathrooms and locker rooms were studied for seven schools in Maine. Simulations were done in water-use rooms where radon in air detectors were in place. Quantities measured were radon in water (270-24500 F) and air (0-80 q), volume of water used, emissivities (0.01-0.99) and ventilation rates (0.012-0.066A). Variation throughout the room of the radon concentration was found. Values calculated for the transfer coefficient for kitchens and baths were ranged from 9.6 x to 2.0 x The transfer coefficient was calculated using these parameters and was also measured using concentrations of radon in water and air. This provides a means by which radon in air can be estimated using the transfer coefficient and the concentration in the water in other schools and it can be used to estimate the dose caused by radon released from water use. This project was partially funded by the United States Environmental Protection Agency (grant #X828l2 101-0) and by the State of Maine (grant #10A500178). These are the first measurements of this type to be done in schools in the United States.
Recommended Citation
Norris, Mary Jo, "A Study of Radon in Air and Water in Maine Schools" (2002). Electronic Theses and Dissertations. 327.
https://digitalcommons.library.umaine.edu/etd/327